The Victron Lynx Distributor M10 is a modular DC distribution rail with four individually fused outputs. It makes a powerful 12V, 24V or 48V installation easy to manage, expandable and well protected.
Each fuse has a status indicator on the front. In combination with a Lynx Smart BMS, fuse information can also be transmitted digitally.
Why a Lynx Distributor? ▾
- Four fused positive outputs and four negative connections.
- Continuously rated up to 1000A DC.
- Local LED indication of power and fuse status.
- Modularly connectable with other Lynx M10 components.
- Neat, shielded solution for high-current DC distribution.
Specifications & dimensions ▾
9–60V DC
12V, 24V and 48V
1000A DC
M10
M8
MEGA, ordered separately
290 × 170 × 80 mm
2.2 kg
IP22
Integration into the Lynx system ▾
The Distributor is mounted directly next to other Lynx modules using the M10 connection. The included RJ10 cable provides power and communication.
- With a Lynx Smart BMS, up to four Distributors can report fuse status.
- With a Lynx Shunt VE.Can, fuse status is only visible locally.
- The Lynx Distributor does not contain a main fuse for the battery bank; design the main protection separately.
Installation & fuses ▾
- Choose a MEGA fuse for each circuit that suits the cable cross-section and connected equipment.
- Use cable lugs and mounting hardware with the correct size and tightening torques.
- Mount the module in a dry, accessible location and protected from mechanical stress.
- De-energize the installation before fuses or cables are installed.
What else do you usually need? ▾
- MEGA fuses for the four outputs.
- Battery and device cables with M8 cable lugs.
- A suitable main fuse for the battery bank.
- Optionally a Lynx Smart BMS NG or Lynx Shunt VE.Can.
- Additional Lynx modules depending on the system design.
FAQ ▾
Are the fuses included?
No. Choose the four MEGA fuses separately based on the connected circuits.
What does M10 mean?
M10 refers to the connection between Lynx modules. The cable and fuse connections in the Distributor are M8.
Can I view the fuse status remotely?
Yes, when the Distributor communicates with a Lynx Smart BMS and the system is monitored via a GX device.