{"product_id":"xenteq-isolatiebewaker-230vac-25a","title":"Xenteq Isolation Monitor 230Vac 25A","description":"\u003cstyle\u003e\n\/* ===== SCOPE: alleen binnen #fe-isg230-25-desc ===== *\/\n#fe-isg230-25-desc p{margin:8px 0}\n#fe-isg230-25-desc ul{margin:8px 0 10px 1.2em}\n#fe-isg230-25-desc li{margin:4px 0}\n#fe-isg230-25-desc .disclaimer{font-size:.95em; opacity:.8;}\n#fe-isg230-25-desc .note{\n  font-size:.95em; background:#fff; border-left:3px solid #ffd24d;\n  padding:8px 10px; border-radius:6px; margin:8px 0;\n}\n\n\/* Badges *\/\n#fe-isg230-25-desc .badges{display:flex; flex-wrap:wrap; gap:8px; margin:8px 0 6px}\n#fe-isg230-25-desc .badge{\n  font-size:.9em; border:1px solid #e6e6e6; border-radius:999px; padding:6px 10px; background:#fff;\n}\n\n\/* Accordions *\/\n#fe-isg230-25-desc details{\n  border-top:1px solid #e6e6e6; padding:8px 0; margin:0; position:relative; z-index:1;\n}\n#fe-isg230-25-desc details:last-of-type{border-bottom:1px solid #e6e6e6;}\n#fe-isg230-25-desc summary{\n  list-style:none; cursor:pointer; padding:10px 0; margin:0;\n  display:flex; align-items:center; justify-content:space-between; font-weight:600;\n}\n#fe-isg230-25-desc summary::-webkit-details-marker{display:none;}\n#fe-isg230-25-desc summary .caret{\n  transition:transform .28s ease; width:10px; height:10px; flex:0 0 10px; position:relative;\n}\n#fe-isg230-25-desc summary .caret::before{\n  content:\"\"; display:block; width:10px; height:10px;\n  border-right:2px solid #333; border-bottom:2px solid #333;\n  transform:rotate(-45deg); position:absolute; top:0; left:0;\n}\n#fe-isg230-25-desc details[open] summary .caret{transform:rotate(180deg);}\n\n\/* Smooth animation *\/\n#fe-isg230-25-desc .acc-panel{\n  max-height:0; overflow:hidden; opacity:0;\n  transition:max-height .32s ease, opacity .32s ease;\n  will-change:max-height;\n}\n#fe-isg230-25-desc details[open] .acc-panel{ max-height:2000px; opacity:1; }\n@media (prefers-reduced-motion: reduce){\n  #fe-isg230-25-desc .acc-panel{ transition:none; }\n  #fe-isg230-25-desc summary .caret{ transition:none; }\n}\n\n\/* Feature cards *\/\n#fe-isg230-25-desc .feature{\n  border:1px solid #e6e6e6; border-radius:10px;\n  padding:10px 12px; background:#fafafa; box-shadow:0 1px 0 rgba(0,0,0,.03);\n  margin-top:10px;\n}\n#fe-isg230-25-desc .feature h4{margin:2px 0 6px; font-size:1.05em}\n#fe-isg230-25-desc .feature ul{margin:6px 0 6px 1.2em}\n#fe-isg230-25-desc .feature li{margin:3px 0}\n\n\/* CTA-knoppen *\/\n:root{--fe-accent:#2ca24f;}\n#fe-isg230-25-desc .fe-actions{\n  display:flex; gap:10px; flex-wrap:wrap; align-items:center; margin:8px 0 2px; position:relative; z-index:3;\n}\n#fe-isg230-25-desc a.fe-cta{\n  display:inline-flex; align-items:center; justify-content:center; gap:8px;\n  padding:10px 14px; border-radius:999px; line-height:1.1;\n  border:1px solid #d9d9d9 !important; background:#fff !important; color:#111 !important;\n  font-weight:600; font-size:15px; text-decoration:none; transition:all .15s ease;\n}\n#fe-isg230-25-desc a.fe-cta:focus-visible{outline:2px solid #0ea5e9; outline-offset:3px}\n#fe-isg230-25-desc a.fe-cta--primary{border-color:var(--fe-accent) !important; color:#0f321a !important;}\n#fe-isg230-25-desc a.fe-cta--primary:hover{background:var(--fe-accent) !important; color:#fff !important; border-color:var(--fe-accent) !important;}\n#fe-isg230-25-desc a.fe-cta--outline{opacity:.95}\n#fe-isg230-25-desc a.fe-cta--outline:hover{border-color:#bbb !important; background:#f7f7f7 !important}\n#fe-isg230-25-desc .fe-cta__arrow{font-weight:700; color:var(--fe-accent)}\n#fe-isg230-25-desc a.fe-cta--primary:hover .fe-cta__arrow{color:#fff}\n\n\/* Separator *\/\n#fe-isg230-25-desc .thin-sep{border-top:1px solid #e6e6e6; margin:12px 0}\n\u003c\/style\u003e\u003cdiv id=\"fe-isg230-25-desc\"\u003e\n\n  \u003c!-- Intro + badges --\u003e\n  \u003cp\u003e\n    The \u003cstrong\u003eXenteq ISG 230-25\u003c\/strong\u003e is an \u003cstrong\u003einsulation safeguard\u003c\/strong\u003e for 230V installations with an\n    \u003cstrong\u003eIT power system\u003c\/strong\u003e (such as with an inverter or generator). The device continuously monitors the insulation resistance and\n    \u003cstrong\u003eautomatically switches off the 230V output\u003c\/strong\u003e in case of a fault from phase or neutral to earth.\n  \u003c\/p\u003e\n\n\n  \u003cdiv class=\"badges\" aria-label=\"Product features\"\u003e\n\n    \u003cspan class=\"badge\"\u003e230 Vac\u003c\/span\u003e\n    \u003cspan class=\"badge\"\u003e25 A\u003c\/span\u003e\n    \u003cspan class=\"badge\"\u003eUp to ±5750 W\u003c\/span\u003e\n    \u003cspan class=\"badge\"\u003eSelf-test (±10 s)\u003c\/span\u003e\n    \u003cspan class=\"badge\"\u003eAlarm 46 kΩ \/ 23 kΩ\u003c\/span\u003e\n    \u003cspan class=\"badge\"\u003eIP66\u003c\/span\u003e\n    \u003cspan class=\"badge\"\u003e5-year warranty\u003c\/span\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- ACCORDIONS --\u003e\n  \u003cdetails id=\"wat-is-het\"\u003e\n    \u003csummary\u003e\u003cspan class=\"acc-label\"\u003eWhat is an insulation safeguard?\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"caret\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\n    \u003cdiv class=\"acc-panel\"\u003e\n\n      \u003cp\u003e\n        In a residential home, personal safety is ensured by a residual current device (RCD) and an earth pin. An inverter\/generator often creates\n        an \u003cstrong\u003eisolated neutral system\u003c\/strong\u003e (IT system). This requires a different approach.\n      \u003c\/p\u003e\n\n\n      \u003cdiv class=\"feature\"\u003e\n\n        \u003ch4\u003eWhat exactly does the ISG 230-25 do?\u003c\/h4\u003e\n\n        \u003cul\u003e\n\n          \u003cli\u003eContinuously monitors the \u003cstrong\u003einsulation resistance\u003c\/strong\u003e of the 230V system.\u003c\/li\u003e\n\n          \u003cli\u003eProvides a \u003cstrong\u003epre-warning\u003c\/strong\u003e when insulation decreases (alarm 1).\u003c\/li\u003e\n\n          \u003cli\u003e\n\n\u003cstrong\u003eSwitches off the output\u003c\/strong\u003e as soon as the insulation resistance becomes too low (alarm 2).\u003c\/li\u003e\n\n        \u003c\/ul\u003e\n\n        \u003cp class=\"disclaimer\"\u003eAccording to the manual, the insulation monitor replaces the RCD in an IT system, where an RCD cannot\/should not be used.\u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n\n      \u003cp class=\"note\"\u003e\n        This product concerns \u003cstrong\u003epersonal safety\u003c\/strong\u003e for 230V from an inverter\/generator. Always have installation performed by a qualified technician.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/details\u003e\n\n  \u003cdetails id=\"voor-wie\"\u003e\n    \u003csummary\u003e\u003cspan class=\"acc-label\"\u003eWhen do you need this in a camper?\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"caret\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\n    \u003cdiv class=\"acc-panel\"\u003e\n\n      \u003cul\u003e\n\n        \u003cli\u003eIf you generate 230V with an \u003cstrong\u003einverter\u003c\/strong\u003e or \u003cstrong\u003ecombi\u003c\/strong\u003e (e.g. Victron MultiPlus) and you also route the 230V “outwards” or to multiple outlets.\u003c\/li\u003e\n\n        \u003cli\u003eIf you have an \u003cstrong\u003eisolated 230V system\u003c\/strong\u003e and want to ensure personal safety technically.\u003c\/li\u003e\n\n        \u003cli\u003eIf your installation operates on both \u003cstrong\u003eshore power\u003c\/strong\u003e and \u003cstrong\u003einverter power\u003c\/strong\u003e and you want to separate them cleanly.\u003c\/li\u003e\n\n      \u003c\/ul\u003e\n\n\n      \u003cdiv class=\"feature\"\u003e\n\n        \u003ch4\u003eWhy specifically the ISG 230-25 (25A)?\u003c\/h4\u003e\n\n        \u003cul\u003e\n\n          \u003cli\u003eSuitable for heavier 230V installations up to \u003cstrong\u003e25A\u003c\/strong\u003e (max. approx. \u003cstrong\u003e5750W\u003c\/strong\u003e).\u003c\/li\u003e\n\n          \u003cli\u003eAccording to Xenteq, this model is also suitable for \u003cstrong\u003ecombi devices\u003c\/strong\u003e and systems with \u003cstrong\u003epriority\/transfer\u003c\/strong\u003e (such as inverter\/charger combinations).\u003c\/li\u003e\n\n        \u003c\/ul\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/details\u003e\n\n\u003cdetails id=\"aansluiten-multiplus\"\u003e\n  \u003csummary\u003e\u003cspan class=\"acc-label\"\u003eConnecting with Victron MultiPlus (combi inverter\/charger)\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"caret\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\n  \u003cdiv class=\"acc-panel\"\u003e\n\n    \u003cp\u003e\n      In a camper with MultiPlus, you usually have 2 situations: \u003cstrong\u003einverter operation\u003c\/strong\u003e (230V from the battery) and \u003cstrong\u003eshore power operation\u003c\/strong\u003e.\n      The ISG 230-25 is designed to ensure personal safety with an \u003cstrong\u003eisolated 230V system\u003c\/strong\u003e (inverter operation without shore power).\n      As soon as shore power is active, the measurement is disabled via \u003cstrong\u003eMAINS detection\u003c\/strong\u003e.\n    \u003c\/p\u003e\n\n\n    \u003cdiv class=\"feature\"\u003e\n\n      \u003ch4\u003eImportant guidelines (practical)\u003c\/h4\u003e\n\n      \u003cul\u003e\n\n        \u003cli\u003ePlace the insulation monitor \u003cstrong\u003ebetween the AC output of the MultiPlus\u003c\/strong\u003e and your 230V distribution (circuit breakers \/ outlet groups).\u003c\/li\u003e\n\n        \u003cli\u003ePreferably connect the insulation monitor \u003cstrong\u003eas directly as possible to the MultiPlus\u003c\/strong\u003e (i.e., before other peripherals).\u003c\/li\u003e\n\n        \u003cli\u003eFor this 25A model, use \u003cstrong\u003e3-core 2.5 mm²\u003c\/strong\u003e mains cable for INVERTER and OUTPUT (according to Xenteq guideline).\u003c\/li\u003e\n\n        \u003cli\u003eLay an additional \u003cstrong\u003e2-core MAINS detection cable\u003c\/strong\u003e (0.75–1.5 mm²) and connect it to the same shore power supply as the MultiPlus (behind your RCD\/circuit breaker after the CEE input).\u003c\/li\u003e\n\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n\n    \u003cdiv class=\"feature\"\u003e\n\n      \u003ch4\u003eShore power present (also with PowerAssist)\u003c\/h4\u003e\n\n      \u003cp\u003e\n        When shore power is present, the ISG is in \"mains present\" mode and insulation measurement is \u003cstrong\u003edisabled\u003c\/strong\u003e.\n        This also applies if the MultiPlus uses \u003cstrong\u003ePowerAssist\u003c\/strong\u003e (supplementing shore power with battery power).\n      \u003c\/p\u003e\n\n      \u003cul\u003e\n\n        \u003cli\u003ePersonal protection then runs via the \u003cstrong\u003eshore power RCD\u003c\/strong\u003e (campsite\/pedestal) and your own shore power protection in the camper.\u003c\/li\u003e\n\n        \u003cli\u003eAs soon as shore power drops, the ISG restarts measurement (after self-test).\u003c\/li\u003e\n\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n\n    \u003cdiv class=\"feature\"\u003e\n\n      \u003ch4\u003eImportant: N–PE coupling in MultiPlus (for correct operation of the ISG)\u003c\/h4\u003e\n\n      \u003cp\u003e\n        The Victron MultiPlus typically connects \u003cstrong\u003eneutral and earth (N–PE)\u003c\/strong\u003e by default when the inverter is operating and no shore power is present.\n        For correct operation of the Xenteq ISG, the 230V output in off-grid inverter operation must form an \u003cstrong\u003eisolated neutral system\u003c\/strong\u003e.\n      \u003c\/p\u003e\n\n      \u003cul\u003e\n\n        \u003cli\u003eTherefore, disable the function in the MultiPlus settings that \u003cstrong\u003ecouples N–PE\u003c\/strong\u003e during inverter operation without shore power.\u003c\/li\u003e\n\n        \u003cli\u003eAfter that, you can check off-grid whether the system is \"isolated\" (you will often measure approximately \u003cstrong\u003e~115Vac\u003c\/strong\u003e from L to PE and from N to PE, as an indication).\u003c\/li\u003e\n\n      \u003c\/ul\u003e\n\n      \u003cp class=\"disclaimer\"\u003e\n        If you are unsure about the setting or the measurements, please contact us; incorrect settings can lead to unexpected behavior in your 230V network.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n\n    \u003cp class=\"note\"\u003e\n      Note: when shore power is active, the shore power installation (pedestal + your camper input) must be equipped with a properly functioning earth leakage protection.\n      The ISG is intended for personal safety with the IT system in inverter operation (without shore power).\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/details\u003e\n\n  \u003cdetails id=\"montage\"\u003e\n    \u003csummary\u003e\u003cspan class=\"acc-label\"\u003eMounting \u0026amp; installation (brief and practical)\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"caret\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\n    \u003cdiv class=\"acc-panel\"\u003e\n\n      \u003cul\u003e\n\n        \u003cli\u003e\n\n\u003cstrong\u003eOnly by qualified technicians\u003c\/strong\u003e; and \u003cstrong\u003eonly one\u003c\/strong\u003e insulation monitor may be connected per electrical system.\u003c\/li\u003e\n\n        \u003cli\u003eMount as \u003cstrong\u003eclose as possible to the inverter\/combi\u003c\/strong\u003e and keep the cable between inverter and ISG as short as possible.\u003c\/li\u003e\n\n        \u003cli\u003eMount on a flat, stable surface and prevent vibrations\/shocks.\u003c\/li\u003e\n\n        \u003cli\u003eIP66 housing: resistant to dust and water, but always mount neatly and without mechanical stress on the cable glands.\u003c\/li\u003e\n\n      \u003c\/ul\u003e\n\n\n      \u003cdiv class=\"feature\"\u003e\n\n        \u003ch4\u003eTest: Is your 230V output \"isolated\"?\u003c\/h4\u003e\n\n        \u003cp\u003e\n          According to the manual, you check this with a multimeter by measuring from \u003cstrong\u003eL\u003c\/strong\u003e to earth and \u003cstrong\u003eN\u003c\/strong\u003e to earth.\n          In an isolated system, you will measure approximately \u003cstrong\u003e115 Vac\u003c\/strong\u003e on both (indicative). If this is not correct, the source may need to be adjusted\n          (e.g., no fixed connection between N and earth).\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n\n      \u003cdiv class=\"feature\"\u003e\n\n        \u003ch4\u003ePreventing overload\u003c\/h4\u003e\n\n        \u003cp\u003e\n          Xenteq advises installing a \u003cstrong\u003efuse on the output\u003c\/strong\u003e, appropriate to the maximum power of the model, to protect against overload.\n        \u003c\/p\u003e\n\n        \u003cp class=\"disclaimer\"\u003eFuse value and type depend on your 230V distribution network (breaker panel, cable thicknesses, outlet groups). We are happy to assist you with this.\u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/details\u003e\n\n  \u003cdetails id=\"werking-led\"\u003e\n    \u003csummary\u003e\u003cspan class=\"acc-label\"\u003eOperation, LED status and testing\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"caret\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\n    \u003cdiv class=\"acc-panel\"\u003e\n\n      \u003cp\u003e\n        After switching on, the ISG first performs a \u003cstrong\u003eself-test\u003c\/strong\u003e. Only then is the output enabled.\n        Allow for a delay of approximately \u003cstrong\u003e10 seconds\u003c\/strong\u003e.\n      \u003c\/p\u003e\n\n\n      \u003cdiv class=\"feature\"\u003e\n\n        \u003ch4\u003eAlarm levels\u003c\/h4\u003e\n\n        \u003cul\u003e\n\n          \u003cli\u003e\n\n\u003cstrong\u003eAlarm 1 (pre-warning):\u003c\/strong\u003e at \u003cstrong\u003e46 kΩ\u003c\/strong\u003e (LED flashing red). Check the system for faults.\u003c\/li\u003e\n\n          \u003cli\u003e\n\n\u003cstrong\u003eAlarm 2 (shutdown):\u003c\/strong\u003e at \u003cstrong\u003e23 kΩ\u003c\/strong\u003e (LED red). Output is switched off.\u003c\/li\u003e\n\n        \u003c\/ul\u003e\n\n      \u003c\/div\u003e\n\n\n      \u003cdiv class=\"feature\"\u003e\n\n        \u003ch4\u003eLED status (summary)\u003c\/h4\u003e\n\n        \u003cul\u003e\n\n          \u003cli\u003e\n\n\u003cstrong\u003eFlashing green:\u003c\/strong\u003e self-test active\u003c\/li\u003e\n\n          \u003cli\u003e\n\n\u003cstrong\u003eGreen:\u003c\/strong\u003e all good, output active via inverter\/generator\u003c\/li\u003e\n\n          \u003cli\u003e\n\n\u003cstrong\u003eWhite:\u003c\/strong\u003e shore power active, measurement disabled\u003c\/li\u003e\n\n          \u003cli\u003e\n\n\u003cstrong\u003eFlashing red:\u003c\/strong\u003e pre-warning (alarm 1)\u003c\/li\u003e\n\n          \u003cli\u003e\n\n\u003cstrong\u003eRed:\u003c\/strong\u003e output switched off (alarm 2)\u003c\/li\u003e\n\n          \u003cli\u003e\n\n\u003cstrong\u003eFlashing red\/green:\u003c\/strong\u003e self-test unsuccessful (contact Xenteq)\u003c\/li\u003e\n\n        \u003c\/ul\u003e\n\n      \u003c\/div\u003e\n\n\n      \u003cdiv class=\"feature\"\u003e\n\n        \u003ch4\u003eMonthly self-test (recommended)\u003c\/h4\u003e\n\n        \u003cul\u003e\n\n          \u003cli\u003ePress \u003cstrong\u003eTest\u003c\/strong\u003e → the ISG creates a fault and switches off.\u003c\/li\u003e\n\n          \u003cli\u003eThen press \u003cstrong\u003eReset\u003c\/strong\u003e → self-test again, then active again if all is OK.\u003c\/li\u003e\n\n        \u003c\/ul\u003e\n\n      \u003c\/div\u003e\n\n\n      \u003cp class=\"disclaimer\"\u003eThe ISG can reset automatically when the power source is re-energized, or manually via the reset button.\u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/details\u003e\n\n  \u003cdetails id=\"specs\"\u003e\n    \u003csummary\u003e\u003cspan class=\"acc-label\"\u003eSpecifications (ISG 230-25)\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"caret\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\n    \u003cdiv class=\"acc-panel\"\u003e\n\n      \u003cul\u003e\n\n        \u003cli\u003e\n\n\u003cstrong\u003eModel:\u003c\/strong\u003e ISG 230-25\u003c\/li\u003e\n\n        \u003cli\u003e\n\n\u003cstrong\u003eMains voltage:\u003c\/strong\u003e 180–250 Vac\u003c\/li\u003e\n\n        \u003cli\u003e\n\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n        \u003cli\u003e\n\n\u003cstrong\u003eMax. output power:\u003c\/strong\u003e approx. 5750 W\u003c\/li\u003e\n\n        \u003cli\u003e\n\n\u003cstrong\u003eMax. output current:\u003c\/strong\u003e 25 A\u003c\/li\u003e\n\n        \u003cli\u003e\n\n\u003cstrong\u003ePre-warning (alarm 1):\u003c\/strong\u003e 46 kΩ\u003c\/li\u003e\n\n        \u003cli\u003e\n\n\u003cstrong\u003eShutdown (alarm 2):\u003c\/strong\u003e 23 kΩ\u003c\/li\u003e\n\n        \u003cli\u003e\n\n\u003cstrong\u003eSuitable for combination with mains voltage:\u003c\/strong\u003e yes\u003c\/li\u003e\n\n        \u003cli\u003e\n\n\u003cstrong\u003eExternal signal on alarm 1:\u003c\/strong\u003e yes (n.o. or n.c.)\u003c\/li\u003e\n\n        \u003cli\u003e\n\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -25°C to +50°C\u003c\/li\u003e\n\n        \u003cli\u003e\n\n\u003cstrong\u003eIP rating:\u003c\/strong\u003e IP66\u003c\/li\u003e\n\n        \u003cli\u003e\n\n\u003cstrong\u003eConnections:\u003c\/strong\u003e input via cable gland M20, output via cable gland M20, MAINS detection via cable gland M20\u003c\/li\u003e\n\n        \u003cli\u003e\n\n\u003cstrong\u003eWeight:\u003c\/strong\u003e approx. 0.45 kg\u003c\/li\u003e\n\n      \u003c\/ul\u003e\n\n      \u003cp class=\"disclaimer\"\u003eSpecifications according to Xenteq ISG-series manual \/ datasheet.\u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/details\u003e\n\n  \u003cdetails id=\"faraday\"\u003e\n    \u003csummary\u003e\u003cspan class=\"acc-label\"\u003eWhy via Faraday Energy?\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"caret\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\n    \u003cdiv class=\"acc-panel\"\u003e\n\n      \u003cul\u003e\n\n        \u003cli\u003eWe often combine this product with Victron MultiPlus installations and know where things can go wrong in practice (detection, sequence in 230V chain, distribution).\u003c\/li\u003e\n\n        \u003cli\u003eQuick check of your diagram: \"where exactly should it be placed\" and \"how to correctly connect MAINS detection.\"\u003c\/li\u003e\n\n        \u003cli\u003eWe help plan a neat 230V distribution: circuit breakers, outlet groups, and fuses suitable for your setup.\u003c\/li\u003e\n\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/details\u003e\n\n  \u003cdetails id=\"advies\"\u003e\n    \u003csummary\u003e\u003cspan class=\"acc-label\"\u003eNeed help with connection?\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"caret\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\n    \u003cdiv class=\"acc-panel\"\u003e\n\n      \u003cp\u003eSend us the following, so we can assist you effectively:\u003c\/p\u003e\n\n      \u003cul\u003e\n\n        \u003cli\u003eWhich device generates 230V: \u003cstrong\u003eMultiPlus model\u003c\/strong\u003e (e.g., 12\/1600, 12\/3000, 24\/3000) or other inverter\u003c\/li\u003e\n\n        \u003cli\u003eA photo or sketch of your 230V distribution (shore power → MultiPlus → groups\/outlets)\u003c\/li\u003e\n\n        \u003cli\u003eHow you use the 230V: only indoors, or also outdoors\/externally\u003c\/li\u003e\n\n      \u003c\/ul\u003e\n\n\n      \u003cdiv class=\"fe-actions\"\u003e\n\n        \u003ca class=\"fe-cta fe-cta--primary\" href=\"https:\/\/wa.me\/31638629787\"\u003eWhatsApp: 06-38629787 \u003cspan class=\"fe-cta__arrow\"\u003e→\u003c\/span\u003e\u003c\/a\u003e\n        \u003ca class=\"fe-cta fe-cta--outline\" href=\"\/en\/pages\/contact\"\u003eContact\u003c\/a\u003e\n        \u003ca class=\"fe-cta fe-cta--outline\" href=\"mailto:info@faradayenergy.nl\"\u003eEmail us\u003c\/a\u003e\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/details\u003e\n\n\u003c\/div\u003e\n\n\u003cscript\u003e\n\/* ===== Smooth accordion + start dicht + max 1 open + deeplink ===== *\/\n(function(){\n  var root = document.getElementById('fe-isg230-25-desc');\n  if(!root) return;\n\n  function closeSiblings(current){\n    root.querySelectorAll('details[open]').forEach(function(d){\n      if(d !== current) d.removeAttribute('open');\n    });\n  }\n\n  function init(){\n    var items = root.querySelectorAll('details');\n    if(!items.length) return;\n\n    \/\/ Start: alles dicht\n    items.forEach(function(d){ d.removeAttribute('open'); });\n\n    \/\/ Deep-link (#id) -\u003e open dat item\n    try{\n      var hash = (location.hash || '').slice(1);\n      if(hash){\n        var el = root.querySelector('#'+CSS.escape(hash));\n        var det = el ? (el.tagName \u0026\u0026 el.tagName.toLowerCase()==='details' ? el : el.closest('details')) : null;\n        if(det){ det.setAttribute('open','open'); det.scrollIntoView({block:'start'}); }\n      }\n    }catch(e){}\n  }\n\n  \/\/ Max 1 open tegelijk\n  root.addEventListener('toggle', function(e){\n    var d = e.target;\n    if(d \u0026\u0026 d.tagName \u0026\u0026 d.tagName.toLowerCase()==='details' \u0026\u0026 d.open){\n      closeSiblings(d);\n    }\n  }, true);\n\n  if(document.readyState === 'loading'){\n    document.addEventListener('DOMContentLoaded', init);\n  } else {\n    init();\n  }\n  document.addEventListener('shopify:section:load', init);\n})();\n\u003c\/script\u003e","brand":"Faraday Energy","offers":[{"title":"Default Title","offer_id":52910542389588,"sku":"XENISO25A","price":299.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9171\/5668\/files\/xenteq-isg-230-25-isolatiebewaker-230v-25a-bovenaanzicht.jpg?v=1767995755","url":"https:\/\/faradayenergy.nl\/en\/products\/xenteq-isolatiebewaker-230vac-25a","provider":"Faraday Energy","version":"1.0","type":"link"}