{"product_id":"victron-lynx-shunt-ve-can-m10","title":"Victron Lynx Smart BMS (M10)","description":"\u003cstyle\u003e#fe-vilyn040102110-desc{line-height:1.5}#fe-vilyn040102110-desc .fe-intro{margin:0 0 12px}#fe-vilyn040102110-desc .fe-bullets{margin:8px 0 0;padding-left:18px}#fe-vilyn040102110-desc details{border:1px solid rgba(0,0,0,.12);border-radius:10px;margin:10px 0;overflow:hidden}#fe-vilyn040102110-desc summary{cursor:pointer;padding:12px 14px;font-weight:600;list-style:none;display:flex;align-items:center;justify-content:space-between;background:rgba(0,0,0,.03)}#fe-vilyn040102110-desc summary::-webkit-details-marker{display:none}#fe-vilyn040102110-desc summary .chev{transition:transform .2s ease}#fe-vilyn040102110-desc details[open] summary .chev{transform:rotate(180deg)}#fe-vilyn040102110-desc .acc-panel{padding:12px 14px;background:#fff}#fe-vilyn040102110-desc .note{background:rgba(0,0,0,.04);border-radius:10px;padding:10px 12px;margin:10px 0}#fe-vilyn040102110-desc .spec-grid{display:grid;grid-template-columns:1fr;gap:8px;margin:8px 0 0}#fe-vilyn040102110-desc .spec-grid div{padding:10px 12px;border:1px solid rgba(0,0,0,.10);border-radius:10px}@media(min-width:700px){#fe-vilyn040102110-desc .spec-grid{grid-template-columns:1fr 1fr}}#fe-vilyn040102110-desc a{text-decoration:underline}\u003c\/style\u003e\u003cdiv id=\"fe-vilyn040102110-desc\"\u003e\n\n\u003cp class=\"fe-intro\"\u003eThe \u003cstrong\u003eVictron Lynx Shunt VE.Can (M10)\u003c\/strong\u003e combines a 1000A shunt for battery monitoring with a place for the main fuse and VE.Can communication to a GX device.\u003c\/p\u003e\n\n\u003cdetails\u003e\u003csummary\u003eMain features \u003cspan class=\"chev\"\u003e▾\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv class=\"acc-panel\"\u003e\u003cul class=\"fe-bullets\"\u003e\n\n\u003cli\u003eCentral current measurement and battery monitoring in a Lynx system.\u003c\/li\u003e\n\n\u003cli\u003eContinuous current rating 1000A.\u003c\/li\u003e\n\n\u003cli\u003ePlace for a main fuse or fuse dummy.\u003c\/li\u003e\n\n\u003cli\u003eVE.Can connection for GX device and VRM display.\u003c\/li\u003e\n\n\u003cli\u003eTemperature sensor and potential-free alarm contact.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eSpecifications \u003cspan class=\"chev\"\u003e▾\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv class=\"acc-panel\"\u003e\u003cdiv class=\"spec-grid\"\u003e\n\n\u003cdiv\u003e\n\n\u003cstrong\u003eSupply range\u003c\/strong\u003e\u003cbr\u003e9–70V DC\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cstrong\u003eSystem voltages\u003c\/strong\u003e\u003cbr\u003e12V, 24V and 48V\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cstrong\u003eCurrent rating\u003c\/strong\u003e\u003cbr\u003e1000A continuous\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003cbr\u003eVE.Can via RJ45\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cstrong\u003eBusbar\u003c\/strong\u003e\u003cbr\u003eM10\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cstrong\u003eDimensions (h × w × d)\u003c\/strong\u003e\u003cbr\u003e190 × 180 × 80mm\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cstrong\u003eWeight\u003c\/strong\u003e\u003cbr\u003e1.4kg\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cstrong\u003eProtection\u003c\/strong\u003e\u003cbr\u003eIP22\u003c\/div\u003e\n\n\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eApplication and compatibility \u003cspan class=\"chev\"\u003e▾\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv class=\"acc-panel\"\u003e\u003cp\u003eSuitable for Lynx M10 systems with lead-acid or lithium batteries when central battery monitoring is desired. For Victron Lithium NG with active BMS protection, a compatible Lynx Smart BMS NG is usually the logical choice.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eInstallation and points to consider \u003cspan class=\"chev\"\u003e▾\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv class=\"acc-panel\"\u003e\u003cp\u003ePlace the shunt in the main negative cable so that all charging and discharging currents are measured. Choose the main fuse suitable for the battery bank, cables and system. For VE.Can, correct terminators are required.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eFrequently asked questions \u003cspan class=\"chev\"\u003e▾\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv class=\"acc-panel\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs a GX device mandatory?\u003c\/strong\u003e\u003cbr\u003eFor local shunt operation not necessarily, but a GX device is needed to view data centrally and in VRM via VE.Can.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the main fuse included?\u003c\/strong\u003e\u003cbr\u003eCheck the supplied version; the fuse value must always be matched to the system.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\u003c\/details\u003e\u003cscript\u003e(function(){const root=document.getElementById('fe-vilyn040102110-desc');if(!root)return;const ds=Array.from(root.querySelectorAll('details'));ds.forEach(d=\u003e{d.open=false;d.addEventListener('toggle',()=\u003e{if(d.open)ds.forEach(o=\u003e{if(o!==d)o.open=false})})})})();\u003c\/script\u003e\n\n\u003c\/div\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":56746864214356,"sku":"VILYN040102110","price":397.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9171\/5668\/files\/victron-lynx-shunt-ve-can-m10.webp?v=1793186271","url":"https:\/\/faradayenergy.nl\/en\/products\/victron-lynx-shunt-ve-can-m10","provider":"Faraday Energy","version":"1.0","type":"link"}