{"product_id":"victron-lynx-class-t-power-in-m10","title":"Victron Lynx Class-T Power In (M10)","description":"\u003cstyle\u003e#fe-vilyn060404010-desc{line-height:1.5}#fe-vilyn060404010-desc .fe-intro{margin:0 0 12px}#fe-vilyn060404010-desc .fe-bullets{margin:8px 0 0;padding-left:18px}#fe-vilyn060404010-desc details{border:1px solid rgba(0,0,0,.12);border-radius:10px;margin:10px 0;overflow:hidden}#fe-vilyn060404010-desc summary{cursor:pointer;padding:12px 14px;font-weight:600;list-style:none;display:flex;align-items:center;justify-content:space-between;background:rgba(0,0,0,.03)}#fe-vilyn060404010-desc summary::-webkit-details-marker{display:none}#fe-vilyn060404010-desc summary .chev{transition:transform .2s ease}#fe-vilyn060404010-desc details[open] summary .chev{transform:rotate(180deg)}#fe-vilyn060404010-desc .acc-panel{padding:12px 14px;background:#fff}#fe-vilyn060404010-desc .note{background:rgba(0,0,0,.04);border-radius:10px;padding:10px 12px;margin:10px 0}#fe-vilyn060404010-desc .spec-grid{display:grid;grid-template-columns:1fr;gap:8px;margin:8px 0 0}#fe-vilyn060404010-desc .spec-grid div{padding:10px 12px;border:1px solid rgba(0,0,0,.10);border-radius:10px}@media(min-width:700px){#fe-vilyn060404010-desc .spec-grid{grid-template-columns:1fr 1fr}}#fe-vilyn060404010-desc a{text-decoration:underline}\u003c\/style\u003e\u003cdiv id=\"fe-vilyn060404010-desc\"\u003e\n\n\u003cp class=\"fe-intro\"\u003eThe \u003cstrong\u003eVictron Lynx Class-T Power In (M10)\u003c\/strong\u003e connects and protects up to two lithium battery strings within the modular Lynx distribution system. The two Class-T fuses are selected and supplied separately.\u003c\/p\u003e\n\n\u003cdetails\u003e\u003csummary\u003eKey features \u003cspan class=\"chev\"\u003e▾\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv class=\"acc-panel\"\u003e\u003cul class=\"fe-bullets\"\u003e\n\n\u003cli\u003eTwo fused connections for batteries or DC equipment.\u003c\/li\u003e\n\n\u003cli\u003eSpace for two Class-T fuses.\u003c\/li\u003e\n\n\u003cli\u003eM10 connection points for connecting to other Lynx M10 modules.\u003c\/li\u003e\n\n\u003cli\u003eContinuous module rating of 1000A at 9–60V DC.\u003c\/li\u003e\n\n\u003cli\u003eSuitable for use on the battery side of a Lynx system.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eSpecifications \u003cspan class=\"chev\"\u003e▾\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv class=\"acc-panel\"\u003e\u003cdiv class=\"spec-grid\"\u003e\n\n\u003cdiv\u003e\n\n\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003cbr\u003e9–60V DC\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cstrong\u003eCurrent rating\u003c\/strong\u003e\u003cbr\u003e1000A continuous\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cstrong\u003eNumber of fuses\u003c\/strong\u003e\u003cbr\u003e2 × Class-T, available separately\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cstrong\u003eLynx busbar\u003c\/strong\u003e\u003cbr\u003eM10\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003cbr\u003e279 × 169 × 97mm\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cstrong\u003eWeight\u003c\/strong\u003e\u003cbr\u003e2.1kg\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003cbr\u003eIP20\u003c\/div\u003e\n\n\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eApplication and compatibility \u003cspan class=\"chev\"\u003e▾\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv class=\"acc-panel\"\u003e\u003cp\u003eCan be combined with other Lynx M10 modules, such as Lynx Smart BMS NG, Lynx Shunt VE.Can, Lynx Distributor and Lynx Power In. Select the Class-T fuses based on the cable, battery and maximum system current.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eInstallation and important points \u003cspan class=\"chev\"\u003e▾\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv class=\"acc-panel\"\u003e\u003cp\u003eHave the design and installation of high-current DC systems carried out or checked by a qualified professional. Work on de-energized equipment, use suitable cable lugs and follow the specified tightening torques. Fuses are not included.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eFrequently asked questions \u003cspan class=\"chev\"\u003e▾\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv class=\"acc-panel\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhich Class-T fuses are suitable?\u003c\/strong\u003e\u003cbr\u003eThe module is designed for suitable Class-T fuses. The exact rating is determined by the battery, cabling and system current.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I connect more than two battery strings?\u003c\/strong\u003e\u003cbr\u003eUse multiple Lynx Class-T Power In modules for three or more strings.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\u003c\/details\u003e\u003cscript\u003e(function(){const root=document.getElementById('fe-vilyn060404010-desc');if(!root)return;const ds=Array.from(root.querySelectorAll('details'));ds.forEach(d=\u003e{d.open=false;d.addEventListener('toggle',()=\u003e{if(d.open)ds.forEach(o=\u003e{if(o!==d)o.open=false})})})})();\u003c\/script\u003e\n\n\u003c\/div\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":56746864083284,"sku":"VILYN060404010","price":190.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0809\/9171\/5668\/files\/victron-lynx-class-t-power-in-m10.webp?v=1793186271","url":"https:\/\/faradayenergy.nl\/en\/products\/victron-lynx-class-t-power-in-m10","provider":"Faraday Energy","version":"1.0","type":"link"}